Search for »*«
21630 search results
-
Leak detection systems for double-skin tanks or double-skin pipes
A leak detection system is used to monitor the tightness of both the primary and the secondary skin of a double-skin tank or pipe within the meaning of water legislation. For this purpose, any deviati -
Leak detection linings for tanks and pipes
Leak detection linings serve to create a second skin within the meaning of water legislation in single-skin tanks or containers. For this purpose, an internal lining is inserted into a single-skin tan -
Drainage pumps for drainage systems
Drainage pumps for drainage systems are used for lifting greywater or foul water, which can contain different components of organic, inorganic or mineral origin. Drainage pumps for drainage systems ar -
Surface protection systems
The term surface protection system covers a range of different types and designs. Besides polymer-containing coatings for concrete structures, organosilicon compounds can also be used as water repelle -
Special punching shear and shear reinforcement
Punching shear reinforcements are special reinforcements used in place of stirrups or bent reinforcements to increase the punching shear resistance in the area of beam supports for reinforced concrete -
Thermal insulation and, where applicable, sound insulation
With their very low thermal conductivities, insulation products play an important role in thermal insulation and in improving the energy performance of buildings. A multitude of different materials ar -
Inverted roof
An inverted roof is an arrangement in which the thermal insulation system is positioned above the roof waterproofing. Due to this special 'upside down' arrangement, both the insulation products (XPS a -
Spray polyurethane foam roofing
Spray polyurethane foam (SPF) roofing systems are composed of an in situ insulation layer made of spray polyurethane foam and a surface protection layer. The systems are used for roofs that are walk-o -
Perimeter insulation
Construction techniques and construction products (usually XPS, EPS or foam glass boards) for perimeter insulation of walls and basement floors in contact with the ground must meet special requirement -
Insulation products under load-bearing elements
Insulation products under load-bearing elements (outside the waterproofing) must not only have special thermal insulation properties, but also meet structural requirements. Frequently used products in -
Insulating render systems
Insulating render systems contain, apart from the usual render components, aggregates such as polystyrene, perlite or an aerogel. The insulation performance achieved in this way is comparable to that -
Ground anchors
Ground anchors are prestressed anchor systems for transmitting tensile forces into the load-bearing ground, e.g. for anchoring shoring systems or slope stabilisation. Ground anchors consist of tendons -
Combined pile/slab foundations
Combined pile/slab foundations are defined in DIN 1054:2021-04 as geotechnical composites consisting of a foundation slab and piles or diaphragm wall elements. This form of foundation engineering is u -
Jet grouting, high-pressure grouting
Jet our high-pressure grouting serves to produce structural elements (jet-grouted elements and/or jet-grouted bodies of soil made of jet-grouted elements) in the soil. These procedures are soil-streng -
Soil injection products
Soil injection products are products used for injection into the subsoil as a pore injection for sealing soil for geotechnical purposes (e.g. construction pit sealing). Earth work and foundation engin -
Soil reinforcement systems
Reinforcement of soil serves to secure escarpments. The inserted geotextiles act via friction and interlocking with the surrounding soil. The stability, e.g. of embankment structures, is increased thr -
Ancillary components and accessories for masonry
Ancillary components and accessories comprise all construction products which, in addition to masonry units and mortar, are needed for the erection of masonry structures. These construction products a -
Facade systems with mechanically fixed cladding
For these facade systems, the external wall cladding is fixed mechanically to the subframe, e.g. with the help of screws, rivets or clip fasteners. The facade systems can be executed as ventilated or -
Facade systems with bonded facade cladding
Facade systems with bonded facade cladding are ventilated external wall claddings where the cladding panels are bonded to the subframe profiles using an interference fit. The subframe is made of metal -
Non-load-bearing internal partitions
Non-load-bearing internal partitions serve to divide rooms. They do not contribute to the stability or bracing of the building. However, there may be requirements with respect to sound insulation, the -
Glued timber and wood-based products and construction techniques
In timber construction, a large variety of glued timber and wood-based products are used for a wide range of uses. These include: glued laminated timber, glued solid timber, plywood, laminated veneer -
Gypsum plasterboards
Gypsum plasterboards and gypsum fibre boards are used in timber construction as cladding for walls and floors. Roofs, walls, facades -
Wood-based panels
Wood-based panels for use in construction include OSB, particleboards, cement-bonded particleboards, fibre boards, plywood, laminated veneer lumber and solid wood panels. A special form of solid timbe -
Timber concrete composite systems
Timber concrete composite systems consist of a timber element and a concrete slab that are joined together in a shear-resistant manner. The shear-resistant bond can be achieved, for example, using scr -
Moisture-variable diffusion inhibiting layers
Moisture-variable diffusion-inhibiting layers are films regulating moisture. They are used, for example, in flat-sloping or pitched, fully insulated, non-ventilated roof constructions with metal roofi