Safety devices with differential pressure monitoring for combined operation of ventilation systems and non-room-sealed heating appliances
Stand-alone safety devices with differential pressure monitoring serve to ensure that ventilation systems and non-room-sealed heating appliances can be operated safely in combined operation mode. For the pressure measurement, the pressure difference is measured either between the heating room (room where the heating appliance is placed or installed) and the connecting flue pipe or between the outside atmosphere and the heating room. If the pressure difference exceeds the defined limit value, the safety device switches the ventilation unit off.
Regulatory framework
In this work area, DIBt grants national technical approvals (abZ) and/or general construction technique permits (aBG). European Technical Assessments (ETAs) can also be issued for corresponding products.
Please also note the applicable design and execution rules for ventilation technology, cf. in particular MVV TB, Parts A and B and the following information and technical rules.
National procedure
To prepare an abZ/aBG for your construction product, we need an application from you. We recommend that you contact us prior to doing so. Feel free to send us your enquiry informally via email to dibt(at)dibt(.)de or to the competent technical contact listed in the top right.
For a first assessment, please send us the following information:
- Description of the construction product and its intended field of use
- e.g. material, configuration, number of sizes, variants, dimensions
- e.g. use in walls, ceilings, interior construction, building services
- Description of the construction technique and its field of application
- e.g. design of walls, ceilings, elements, etc., and interaction of components
- e.g. application in foundation engineering, reinforced concrete construction, building insulation; as load-bearing or non-load-bearing component; under static and quasi-static loading; fire exposure; other environmental exposures
- Information regarding impact on regulatory concerns
- in particular structural integrity, fire protection, health and environment protection, sound insulation as well as thermal performance
- Explanation of need for an abZ/aBG
- Do you significantly deviate from the Technical Building Rules?
- Or do neither Technical Building Rules nor generally recognised technical rules exist?
- Contact details
- preferably email address and/or telephone number, as well as name, organisation/company, and postal address
We will then contact you to clarify the next steps.
If you already hold a DIBt approval and/or construction technique permit and wish to apply for an amendment, supplement, or renewal, please use the form provided below.
- pdf-Datei Application for amendment / supplementation / renewal of a national technical approval and/or construction technique permit (4 pages ) Last updated: 10 April 2024; Application form
European Technical Assessment (ETA)
To start the ETA procedure, please submit the form below. We will then check if the prerequisites for issuing an ETA are met, i.e., in particular, if the product is not fully covered by an existing harmonised standard. If the prerequisites are met, we will check whether a European Assessment Document (EAD) covering the requested assessment scope already exists or still needs to be developed. If an EAD needs to be developed or amended, a complete technical file needs to be established before the procedure can begin.
- pdf-Datei Form for requesting a European Technical Assessment (ETA) (2 pages ) Last updated: 11 March 2025
| Subject concerned | Applicant | Decision no. |
Validity
from / to |
|---|---|---|---|
| Rauchzugwächter Typ "ZP4" und "ZP4plus" als Sicherheitseinrichtungen zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Erich Huber GmbH Feinwerktechnische Systeme Lise-Meitner-Straße 5 82216 Gernlinden | Z-85.1-15 |
Z:
20.10.2025 G: 06.07.2029 |
| LEDA Unterdruck-Controller LUC2 - Eigenständige Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | LEDA Werk GmbH & Co. KG Boekhoff & Co. Groningerstr. 10 26789 Leer | Z-85.1-16 |
Z:
17.12.2024 G: 13.12.2029 |
| Differenzdruckcontroller "DS 01" - Eigenständige Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Wodtke GmbH Rittweg 55-57 72070 Tübingen | Z-85.1-2 |
Z:
09.12.2022 G: 12.12.2027 |
| Funk-Differenzdrucksensor "BL220DD-SD" in Kombination mit den Funk-Abluft-Sicherheitsschalter "BL220F" oder "BL220FI" als Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | BROKO GmbH Max-Planck-Straße 13 85716 Unterschleißheim | Z-85.1-23 |
Z:
04.02.2025 G: 06.02.2030 |
| Funk-Differenzdrucksensor Typ "BL220DD-AD" der Baureihe "BROKO" und "HARK" in Kombination mit dem Funk-Abluft-Sicherheitsschalter "BL220F" oder "BL220FI" als Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | BROKO GmbH Elektroproduktion und Vertrieb Landshuter Straße 1 84048 Mainburg | Z-85.1-24 |
Z:
16.04.2021 G: 16.04.2026 |
| HOXTER Unterdruckwächter "HOS UDW" - Eigenständige Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | HOXTER a.s. Jinacovice 512 664 34 JINACOVICE TSCHECHISCHE REPUBLIK | Z-85.1-26 |
Z:
30.08.2022 G: 30.08.2027 |
| Unterdruckwächter - Eigenständige Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | SUEDWIND GmbH Handwerkerstraße 14 39057 EPPAN (BZ) ITALIEN | Z-85.1-27 |
Z:
31.05.2024 G: 31.05.2029 |
| Differenzdruckwächter "SafeFire" - Eigenständige Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Rüegg Cheminée Schweiz AG Studbachstraße 7 8340 HINWIL SCHWEIZ | Z-85.1-28 |
Z:
25.11.2024 G: 25.11.2029 |
| Unterdruck-Controller "DC Pro+" - Sicherheitseinrichtung für den gemeinsamen, gefahrlosen Betrieb von raumluftabhängigen Feuerstätten und Lüftungsanlagen | CB-tec GmbH Behaimweg 2 87781 Ungerhausen | Z-85.1-29 |
Z:
20.10.2025 G: 20.10.2030 |
| Luftdruckwächter der Typen "P4", "P4 Multi" sowie "P4 Funk" als eigenständige Sicherheitseinrichtung zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Erich Huber GmbH Feinwerktechnische Systeme Lise-Meitner-Straße 5 82216 Gernlinden | Z-85.1-3 |
Z:
01.04.2022 G: 04.04.2027 |
| "USA-UnterdruckSicherheitsAbschalter", "USA3" und "USA4" als eigenständige Sicherheitseinrichtungen zur Gewährleistung eines gefahrlosen gemeinsamen Betriebes von Lüftungsanlagen und raumluftabhängigen Feuerstätten | Ulrich Brunner GmbH Zellhuberring 17-18 84307 Eggenfelden | Z-85.1-8 |
Z:
19.05.2025 G: 19.05.2030 |