Special fire-resistant components
National procedure
To prepare an abZ/aBG for your construction product, we need an application from you. We recommend that you contact us prior to doing so. Feel free to send us your enquiry informally via email to dibt(at)dibt(.)de or to the competent technical contact listed in the top right.
For a first assessment, please send us the following information:
- Description of the construction product and its intended field of use
- e.g. material, configuration, number of sizes, variants, dimensions
- e.g. use in walls, ceilings, interior construction, building services
- Description of the construction technique and its field of application
- e.g. design of walls, ceilings, elements, etc., and interaction of components
- e.g. application in foundation engineering, reinforced concrete construction, building insulation; as load-bearing or non-load-bearing component; under static and quasi-static loading; fire exposure; other environmental exposures
- Information regarding impact on regulatory concerns
- in particular structural integrity, fire protection, health and environment protection, sound insulation as well as thermal performance
- Explanation of need for an abZ/aBG
- Do you significantly deviate from the Technical Building Rules?
- Or do neither Technical Building Rules nor generally recognised technical rules exist?
- Contact details
- preferably email address and/or telephone number, as well as name, organisation/company, and postal address
We will then contact you to clarify the next steps.
If you already hold a DIBt approval and/or construction technique permit and wish to apply for an amendment, supplement, or renewal, please use the form provided below.
- pdf-Datei Application for amendment / supplementation / renewal of a national technical approval and/or construction technique permit (4 pages ) Last updated: 10 April 2024; Application form
European Technical Assessment (ETA)
To start the ETA procedure, please submit the form below. We will then check if the prerequisites for issuing an ETA are met, i.e., in particular, if the product is not fully covered by an existing harmonised standard. If the prerequisites are met, we will check whether a European Assessment Document (EAD) covering the requested assessment scope already exists or still needs to be developed. If an EAD needs to be developed or amended, a complete technical file needs to be established before the procedure can begin.
- pdf-Datei Form for requesting a European Technical Assessment (ETA) (2 pages ) Last updated: 11 March 2025
| Subject concerned | Applicant | Decision no. |
Validity
from / to |
|---|---|---|---|
| Feuerwiderstandsfähiges Installationselement "INSTA-BLOC-Sanitärelement" | Sanitär-Elementbau GmbH Bundesstraße 110 8967 HAUS/ENNSTAL ÖSTERREICH | Z-19.30-2056 |
Z:
18.08.2025 G: 13.08.2030 |
| Bauart zum Errichten von Installationsbauteilen vom Typ "Geberit Quattro 30" für eine Feuerwiderstandsdauer von 30 Minuten | Geberit Vertriebs GmbH Theuerbachstraße 1 88630 Pfullendorf | Z-19.30-2206 |
Z:
13.06.2024 G: 13.06.2029 |
| Bauart zum Errichten von Installationsbauteilen vom Typ "Geberit Quattro 90" für eine Feuerwiderstandsdauer von 90 Minuten | Geberit Vertriebs GmbH Theuerbachstraße 1 88630 Pfullendorf | Z-19.30-2207 |
Z:
13.06.2024 G: 13.06.2029 |
| Installationskanal "Würth Brandschutzkanal" bzw. "Würth Brandschutzkanal A" der Feuerwiderstandsklasse I 120, I 90, I 60 bzw. I 30 nach DIN 4102-11 | Adolf Würth GmbH & Co. KG Reinhold-Würth-Straße 12-17 74653 Künzelsau | Z-19.30-2214 |
Z:
05.09.2023 G: 05.09.2026 |
| Feuerwiderstandsfähiger Installationskanal "PYROMENT-IK90, -IK90 A, -IK90 C." der Feuerwiderstandsklasse I 120, I 90, I 60 bzw. I 30 nach DIN 4102-11 | G+H Isolierung GmbH Leuschner Straße 2 97084 Würzburg | Z-19.30-2231 |
Z:
21.03.2024 G: 21.03.2029 |
| Feuerwiderstandsfähiger Installationskanal "System BSK" bzw. "System BSK A" der Feuerwiderstandsklasse I 120, I 90, I 60 bzw. I 30 nach DIN 4102-11 | FLAMRO Brandschutz-Systeme GmbH Am Sportplatz 2 56291 Leiningen | Z-19.30-2232 |
Z:
28.03.2024 G: 28.03.2029 |
| Feuerwiderstandsfähiger Installationskanal "Instafix BKI" der Feuerwiderstandsklasse I 120, I 90, I 60 bzw. I 30 nach DIN 4102-11 | Wichmann Brandschutzsysteme GmbH & Co. KG Siemensstraße 7 57439 Attendorn | Z-19.30-2524 |
Z:
22.03.2024 G: 26.03.2029 |
| Bauprodukte der Serie "Würth Brandschutzkanal" bzw. "Würth Brandschutzkanal A" für feuerwiderstandsfähige Installationskanäle "Würth Brandschutzkanal" bzw. "Würth Brandschutzkanal A" | Adolf Würth GmbH & Co. KG Reinhold-Würth-Straße 12-17 74653 Künzelsau | Z-19.301-2394 |
Z:
21.08.2023 G: 28.08.2026 |
| Bauprodukte der Serie "PYROMENT-IK90" für feuerwiderstandsfähige Installationskanäle "PYROMENT-IK90" | G+H Isolierung GmbH Leuschner Straße 2 97084 Würzburg | Z-19.301-2438 |
Z:
21.03.2024 G: 31.03.2029 |
| Bauprodukte der Serie "Instafix BKI" für feuerwiderstandsfähige Installationskanäle "Instafix BKI" | Wichmann Brandschutzsysteme GmbH & Co. KG Siemensstraße 7 57439 Attendorn | Z-19.301-2523 |
Z:
21.03.2024 G: 26.03.2029 |
| Bauprodukte der Serie "System BSK" bzw. "System BSK A" für feuerwiderstandsfähige Installationskanäle "System BSK" bzw. "System BSK A" | FLAMRO Brandschutz-Systeme GmbH Am Sportplatz 2 56291 Leiningen | Z-19.301-2525 |
Z:
26.03.2024 G: 26.03.2029 |
| Module und feuerhemmende Bauteile in Kleusberg-Modulbauweise | KLEUSBERG GmbH & Co. KG Grünstraße 14c 06184 Kabelsketal | Z-19.33-2537 |
Z:
14.04.2025 G: 14.04.2030 |
| Module und feuerhemmende Bauteile in ALHO-Modulbauweise | ALHO Holding GmbH Hammer 1 51598 Friesenhagen | Z-19.33-2736 |
Z:
09.09.2025 G: 09.09.2030 |
| Gefahrstoffcontainer Typ BLS ... mit Stahlauffangwannen | Protectoplus GmbH Grüner Kamp 19-21 24768 Rendsburg | Z-19.331-2675 |
Z:
18.10.2023 G: 30.03.2027 |
| Subject concerned | Applicant | Decision no. | Issued on |
|---|---|---|---|
| PYROMENT-IK 90® Typ BD | G+H Isolierung GmbH Leuschner Straße 2 97084 Würzburg DEUTSCHLAND | ETA-15/0293 |
14.01.2026 |
| System FWK Plus | Tehalit GmbH Seebergstraße 37 67716 Heltersberg DEUTSCHLAND | ETA-20/0613 |
14.11.2025 |