EAD 330747-00-0601 Fasteners for use in concrete for redundant non-structural systems ( - 27 pages)
Version: May 2018; OJEU 2018/C 281/04; EOTA
-
EAD 330747-00-0601 Fasteners for use in concrete for redundant non-structural systems ( - 27 pages)
Version: May 2018; OJEU 2018/C 281/04; EOTA
-
Execution and evaluation of job site tests of injection anchor systems for use in masonry with EAD 330076-00-0604 or ETAG 029 (pdf - 28 pages)
Version: September 2019, Translation: December 2021; Technical Rule
-
Execution and evaluation of job site tests of injection anchor systems for use in masonry with EAD 330076-00-0604 or ETAG 029 (pdf - 28 pages)
Version: September 2019, Translation: December 2021; Technical Rule
-
EOTA TR039 Ventilated façade system with self-supporting composite panels ( - 28 pages)
Version: April 2013; EOTA
-
EOTA TR042 Plastics piping kits for heating systems, consisting of pipes made of PB-R and mechanical and or welded fittings ( - 6 pages)
Version: July 2012; EOTA
-
EOTA TR042 Plastics piping kits for heating systems, consisting of pipes made of PB-R and mechanical and or welded fittings ( - 6 pages)
Version: July 2012; EOTA
-
EOTA TR039 Ventilated façade system with self-supporting composite panels ( - 28 pages)
Version: April 2013; EOTA
-
EOTA TR046 Test methods for foam adhesives for External Thermal Insulation Composite Systems (ETICS) ( - 14 pages)
Version: January 2014; EOTA
-
EOTA TR046 Test methods for foam adhesives for External Thermal Insulation Composite Systems (ETICS) ( - 14 pages)
Version: January 2014; EOTA
-
EOTA TR074 Design of wire loop systems for the connection of precast and in-situ concrete elements ( - 5 pages)
April 2020; EOTA
-
EOTA TR074 Design of wire loop systems for the connection of precast and in-situ concrete elements ( - 5 pages)
April 2020; EOTA
-
EAD 200059-00-0302 Steel components for pallet racking systems ( - 12 pages)
Version: January 2018; OJEU 2018/C 417/07; EOTA
-
EAD 330196-01-0604 Plastic anchors made of virgin or non-virgin material for fixing of external thermal insulation composite systems with rendering ( - 42 pages)
Version: July 2017; OJEU 2017/C 379/07; EOTA
-
EAD 330340-00-0606 Factory made structural anchor for attaching personal fall protection equipment, designed to be permanently and fully bonded to a multi-layered roof waterproofing system ( - 22 pages)
Version: October 2018; OJEU 2018/C 417/07; EOTA
-
EAD 331072-00-0601 Anchor devices for fastening personal fall protection systems to concrete structures ( - 16 pages)
Version: October 2017; OJEU 2018/C 417/07; EOTA
-
EAD 331072-00-0601 Anchor devices for fastening personal fall protection systems to concrete structures ( - 16 pages)
Version: October 2017; OJEU 2018/C 417/07; EOTA
-
EAD 330340-00-0606 Factory made structural anchor for attaching personal fall protection equipment, designed to be permanently and fully bonded to a multi-layered roof waterproofing system ( - 22 pages)
Version: October 2018; OJEU 2018/C 417/07; EOTA
-
EAD 330196-01-0604 Plastic anchors made of virgin or non-virgin material for fixing of external thermal insulation composite systems with rendering ( - 42 pages)
Version: July 2017; OJEU 2017/C 379/07; EOTA
-
EAD 330087-00-0601 Systems for post-installed rebar connections with mortar ( - 42 pages)
Version: May 2018; OJEU 2018/C 370/05; EOTA
-
Space frames, connectors, screw connections, mullion/transom connections, fastening systems for photovoltaic systems, mounting rails
profiles as well as fasteners (e.g. screws). Mounting and racking systems for photovoltaic systems are needed to install these systems on the roof or a supporting structure. Self-drilling or tapping screws [...] nodes. At least two frame members are joined at a node. Clamping connections in mullion/transom systems serve to fix facade elements/infill panels, such as glazing. They transmit loads acting perpendicular [...] screwed into the screw channels of the supporting or base profiles. T-connections in mullion/transom systems serve to transmit loads between the mullion and transom profiles. They usually consist of the mullion -
Systems for limiting hydrocarbons in mineral oil containing wastewater from vehicle cleaning facilities (closed-loop systems)
The systems serve to treat wastewater from vehicle cleaning facilities to such an extent that the water can be reused in the washing process (closed-loop systems) or introduced into the sewer system. Systems -
Electric panels for electrical wiring systems for safety systems required under the Building Codes subject to circuit integrity requirements
An electric panel forms part of the electrical wiring system for safety systems required under the Building Codes. The functions of these systems must be maintained in case of fire for the required duration [...] batteries, where applicable, and the electrical wires/cables to be used. Electric panels for safety systems -
Fire protection systems for ventilation systems
exhaust ventilation systems in accordance with DIN 18017-3 or accordingly for systems based on DIN 18017-3 in which supply air is ducted. The components of the fire protection system combined prevent the [...] Fire protection systems mainly consist of straight air duct sections, fittings, seals, connectors and fasteners, classified or unclassified wraps and shut-off devices for fire and smoke etc. They may only [...] other storeys for the verified duration. Construction products for fire protection of ventilation systems -
The German regulatory system for construction products and construction techniques
FAQs on the German regulatory system for construction products and construction techniques 1. What is the applicable legal basis? The German regulatory system for construction products and construction [...] lesser regulatory importance or which are, for example, covered by other certification or approval systems), there are generally recognised technical rules for the construction product (see FAQ "What are [...] for the declaration of conformity is that the manufacturer has set up a factory production control system to ensure that the construction product complies with the relevant technical rules. Where required