Search for »a.a«
20068 search results
-
Barrier glazing
of glass as well as floor-to-ceiling glazing. Usually a glass structure which provides fall protection contains a laminated safety glass which has a favrouable fracture behaviour due to the interlayer used [...] Barrier glazing is glazing designed to prevent people from falling to a lower level. In the event of impact on the glazing, the risk of injury is supposed to be low. Furthermore, the lower-lying traffic -
Surface protection systems
zone) of de-icing agents. OS 11a (OS F a) / OS 11b (OS F b): Coating with increased dynamic crack-bridging capacity for surfaces accessible by foot or vehicle OS 11a (OS F a) / OS 11b (OS F b) is applied [...] Betonbauteile von Wasserbauwerken, ZTV-W LB 219), a distinction is made between the following surface protection systems: OS 1 (OS A): Hydrophobic treatment OS 1 (OS A) is applied to reduce water absorption in [...] de-icing agents. OS 5a (OS DII) / OS 5b (OS DI): Coating with low crack-bridging capacity for surfaces not accessible by foot or vehicle (with scratch coating or levelling filler) OS 5a (OS DII) / OS 5b (OS -
Fixings bonded to the roof waterproofing
roof waterproofing thus takes on a structural role in the transfer of loads, for which it is not designed. As a matter of fact, the roof waterproofing as such is not a load-bearing element. Furthermore -
Walk-on glazing, accessible glazing and glazing with fall-through protection
multiple panes with interlayers. It is common for the top pane to be designed as what is called a wear layer, i.e. a layer which can be destroyed without degrading the load-bearing capacity. Glass in construction [...] Walk-on glazing is designed for foot traffic. A vertical imposed load of maximum 5 kN/m 2 is assumed under normal use conditions. Glazing accessible for maintenance and glazing with fall-through protection -
Z-23.15-2104
Wärmedämmsysteme unter Verwendung der Holzwolle-Mehrschichtplatten "Tektalan A2-Basic", "Tektalan A2-Basic [1.0]", "Tektalan A2-SmartTec", "Tektalan A2-SmartTec [1.0]", "Tektalan A2-SmartTec alpha", "Tektalan A2-SmartTec [1.0] alpha", "Tektalan A2-Lumax", "Tektalan A2-Lumax [1.0]", "Tektalan Basic" und "Tektalan Basic [1.0]"
-
Z-43.12-134
Baustoffe und Bauteile für Speicher-Einzelfeuerstätten mit den Bezeichnungen "Rondolino 144 A/B", "Rondolino 167 A/B", "Rondolino 177 A/B" "Rondolino 210 A/B" und "Rondolino loft 144 A/B" sowie "Rondolino loft 177 A/B"
-
Z-51.3-208
Lüftungsgerät mit Wärmerückgewinnung a²
-
Z-51.3-210
Lüftungsgerät mit Wärmerückgewinnung a³
-
Z-158.10-75
Verlegeunterlage "MONDO EVERLAY A"
-
Anchor channels
An anchor channel is a fastening system that consists of a channel profile with permanently attached anchors and channel bolts. The channel profile with the anchors is fastened to the formwork prior to [...] to concreting and then cast in. The anchor channel is anchored in concrete through a form-fit between the anchor and the concrete member. The element to be attached is later fastened to the embedded channel -
Leakage detection systems in MSS and biogas facilities
(biogas SF facilities), e.g. under storage tanks or basin linings. A leakage detection system usually consists of a sealing membrane with a leakage control device and other accessories (e.g. load-distributing -
Z-56.429-916
Beschichtete Glasfilamentgewebe "Protex 600.1 A2", "Protex 1100.1 A2", "Protex 600 S A2", "Modutex 600 A2", "Ecotex 1100 A2" und beidseitig mit Aluminiumfolie kaschiertes und mit Stahldraht verstärktes zweischichtiges Glasfilamentgewebe "Heliotex" als nichtbrennbare Baustoffe
-
Special fire-resistant components in ventilation technology – duct components
duct components may only be used in a vertical design to prevent the spread of fire from storey to storey for the fire-resistance duration verified for the assembly as a whole. Construction products for fire [...] fire-resistant components in ventilation technology are service duct components consisting mainly of a supporting tray, cladding, supply and discharge lines, electrical cables and ventilation ducts – including -
Z-33.44-63
Wärmedämm-Verbundsysteme mit angeklebten Mineralwolle-Lamellen "weber.therm A 100 MW-L WDVS" "weber.therm A 100 MW-L DP WDVS" "weber.therm A 100 MW-L Speedy WDVS" "weber.therm A 100 MW-L Speedy DP WDVS" "weber.therm A 200 MW-L WDVS" "weber.therm A 200 MW-L DP WDVS" "weber.therm A 200 MW-L Speedy WDVS" "weber.therm A 200 MW-L Speedy DP WDVS"
-
Composite insulation elements
mechanically fixed directly to the load-bearing wall as external wall cladding. A composite insulation element consists of a thermal insulation layer and an outer weather protection layer. Thermal and sound -
Z-33.43-201
Wärmedämm-Verbundsystem mit angeklebtem und angedübeltem Wärmedämmstoff "einzA WDVS Polystyrol PS-D" "einzA WDVS Steinwolle MW-D2" "einzA WDVS Lamelle ML-D2"
-
Closures and closure systems for inspection openings
opening are used to seal revision openings in fire-resistant service ducts or suspended ceilings inside a building or structural work. They prevent fire or smoke from spreading via the revision opening from [...] suspended ceiling to the area below. Closures or closure systems for inspection openings consist mainly of a frame and the leaf or leaves. Closures and closure systems for revision openings are factory-made, need [...] need to close tightly all around; they may only be opened from the outside (i.e. from the room) with a special tool or key or similar. By definition, closures for inspection openings have one or two leaves -
ETA-25/0390
einzA Schimmelschutz Systemplatte einzA Schimmelschutz Laibungsplatte einzA Schimmelschutz Keilplatte
-
Z-33.43-1783
Wärmedämm-Verbundsysteme mit angeklebten und angedübelten Wärmedämmstoffen "einzA WDVS Polystyrol EPS-D" "einzA WDVS Mineralwolle MW-D" "einzA WDVS Lamelle MWL-D"
-
Z-33.43-1751
Wärmedämm-Verbundsysteme mit angedübelten und angeklebten Wärmedämmstoffen "einzA WDVS Polystyrol PS-D" "einzA WDVS Steinwolle MW-D" und "einzA WDVS Lamelle ML-D"
-
Z-156.601-951
Textile Bodenbeläge nach DIN EN 14041 "ecmodular"
-
Stainless steels
this chromium content level, the steels are able to form a complete surface layer of chromium oxide. This oxide layer or passive film constitutes a 'natural' barrier against corrosion, because the film does [...] given above. By the way, following the steel classification set out in EN 10020, stainless steels form a class of their own and are not part of the 'special steel' class. Materials for metal construction -
Z-19.11-1837
Dämmschichtbildende Baustoffe "KAEtherm A" und "KAEtherm A (HF)"
-
Z-158.10-255
Verlegeunterlagen "PEHD Underlays"
-
Z-3.31-1714
Flugasche für Beton "Bergkament-A"