Smoke detection and triggering devices for fire dampers or smoke dampers
Smoke detection and triggering devices are used for controlling and triggering fire and smoke dampers in air ducts of HVAC systems. Following smoke detection and the corresponding signalling, the fire -
Fire-resistant air ducts
Fire-resistant air ducts that are assembled on site from CE-marked fire protective boards covered by a European Technical Assessment (ETA) issued on the basis of a European Assessment Document (EAD) a -
Fire protection systems for ventilation systems
Fire protection systems mainly consist of straight air duct sections, fittings, seals, connectors and fasteners, classified or unclassified wraps and shut-off devices for fire and smoke etc. They may -
Fire dampers and shut-off devices for air ducts for exhaust ventilation systems in accordance with DIN 18017-3
Fire dampers are installed in air ducts of ventilation systems in the area of fire-resistant separating elements to prevent the spread of fire and smoke along the ductwork to other fire compartments f -
Linearly supported glazing
With linearly supported glazing, the glass panes are continuously fixed via a linear mechanical glass support (e.g. profile) with a glass insertion depth. The glazing system is installed in such a man -
Structural sealant glazing
With structural sealant glazing, glass panes are bonded to frame profiles at the factory (primarily using silicone adhesive and with a linear adhesive bead). This prefabricated structural sealant glaz -
Parquet adhesives
Parquet adhesives are used across large surface areas to bond parquet or wood flooring to the substrate. They can consist of one or two components. Acrylate dispersions, epoxides, polyurethanes, silan -
Grease separators
Grease separators serve to separate grease from commercial wastewater. Separator systems -
Separator systems for light liquids
Separator systems for light liquids serve to separate light liquids of mineral origin from commercial wastewater. Separator systems -
Fire-resistant enclosures for electric panels
Fire-resistant enclosures for electric panels separate measuring devices and electric panels from required stairwells and spaces between required stairwells and exits or encase electric panels for saf -
Construction products and techniques for temporary structures
Temporary structures are repeatedly erected and taken down. They include, for example, bleachers, tents and rides for fairgrounds. Temporary structures are special structures within the meaning of Sec -
Membrane structures
Membrane structures are composed of thin, fabric-like materials. Due to their low self-weight, they are suitable for spanning large areas. They are used, e.g., as space-dividing, thermally insulating -
Gabions
Gabions are wire mesh boxes filled with graded aggregate. Individual gabions are assembled via stacking and connecting to form gabion assemblies. These assemblies serve, for example, to stabilise esca -
Binder
Concrete constituents -
Plastic anchors
A plastic fastener consists of a plastic sleeve and a steel or plastic expansion element. The plastic fastener is placed into a pre-drilled hole in the base material and anchored through expansion of -
Space frames, connectors, screw connections, mullion/transom connections, fastening systems for photovoltaic systems, mounting rails
Space frames are three-dimensional frame structures which serve as roof or building structures. They usually consist of frame members (tubes) and nodes. At least two frame members are joined at a node -
Fully digital for the first time: DIBt Annual Report 2023/2024
03.09.2025
After its digital debut, the DIBt Annual Report 2023/2024 is now available in English. The DIBt Annual Report 2023/2024 is now available in the English language. Following its digital debut in the Ger -
Coatings (including inner coatings) and linings in MSS and biogas facilities
Coatings (including inner coatings) and linings are used for creating liquid-tight sealings for collecting trays, collecting rooms and surfaces in storage and filling facilities for manure, slurry and -
Sealing systems made of concrete in MSS and biogas facilities
To create (load-bearing) surface seals in storage and filling facilities for manure, slurry and silage effluent (MSS facilities) and biogas storage and filling facilities (biogas SF facilities), liqui -
Drainage pumps for drainage systems
Drainage pumps for drainage systems are used for lifting greywater or foul water, which can contain different components of organic, inorganic or mineral origin. Drainage pumps for drainage systems ar -
Surface protection systems
The term surface protection system covers a range of different types and designs. Besides polymer-containing coatings for concrete structures, organosilicon compounds can also be used as water repelle -
Grout, corrosion protection systems
Grout is used for filling ducts for internal bonded tendons or sheaths for external tendons. It serves to establish a form and interference fit between the concrete and the prestressing wires and to p -
Injection products and systems
Injection products and systems are used for repairing concrete structures. A distinction is made between different repair objectives. The filling objective 'Closing (crack width control by filling)' i -
Racking systems
Racking systems are structures for storing and retrieving goods in warehouses. The goods to be stored are usually placed on pallets or in grid boxes. Metal products and construction techniques -
Hold-open devices
A hold-open device is a system of devices or device combinations suitable for the controlled disabling of the function of closing devices. Hold-open devices may be used on fire doors, smoke control do