You are here

Internal bonded tendons

For internal bonded post-tensioning, the tendons are arranged in a sheath (tendon duct) which is grouted after the prestressing force has been applied. These post-tensioning systems are used for prestressing concrete members made of normal weight concrete. They are largely designed in accordance with DIN EN 1992-1-1:2011-01 in conjunction with DIN EN 1992-1-1/NA:2013.

Regulatory framework

DIBt grants national technical approvals (abZ) for post-tensioning systems and their components.

European Technical Assessments (ETAs) can also be issued for post-tensioning kits.

Please note that there are no conclusive technical rules for the design and execution of structural works using prestressing systems – except for pre-tensioning at the factory in accordance with DIN EN 1992‑1‑1:2011‑01, Clause 5.10. In cases which are relevant from a regulatory point of view, a construction technique permit (aBG) is generally required. DIBt grants general construction technique permits for prestressing applications.

Note: The lists below may still include approvals for a construction technique, also called 'application approvals'. As a result of the revision of the Model Building Code (MBO) in 2016 followed by the revision of the applicable Building Codes of the federal states (LBO), these are successively being replaced by construction technique permits or will expire.

National procedure

To prepare an abZ/aBG for your construction product, we need an application from you. We recommend that you contact us prior to doing so. Feel free to send us your enquiry informally via email to dibt(at)dibt(.)de or to the competent technical contact listed in the top right.

For a first assessment, please send us the following information:

  • Description of the construction product and its intended field of use
    • e.g. material, configuration, number of sizes, variants, dimensions
    • e.g. use in walls, ceilings, interior construction, building services
  • Description of the construction technique and its field of application
    • e.g. design of walls, ceilings, elements, etc., and interaction of components
    • e.g. application in foundation engineering, reinforced concrete construction, building insulation; as load-bearing or non-load-bearing component; under static and quasi-static loading; fire exposure; other environmental exposures
  • Information regarding impact on regulatory concerns
    • in particular structural integrity, fire protection, health and environment protection, sound insulation as well as thermal performance
  • Explanation of need for an abZ/aBG
  • Contact details
    • preferably email address and/or telephone number, as well as name, organisation/company, and postal address

We will then contact you to clarify the next steps.

If you already hold a DIBt approval and/or construction technique permit and wish to apply for an amendment, supplement, or renewal, please use the form provided below.

European Technical Assessment (ETA)

To start the ETA procedure, please submit the form below. We will then check if the prerequisites for issuing an ETA are met, i.e., in particular, if the product is not fully covered by an existing harmonised standard. If the prerequisites are met, we will check whether a European Assessment Document (EAD) covering the requested assessment scope already exists or still needs to be developed. If an EAD needs to be developed or amended, a complete technical file needs to be established before the procedure can begin.

abZ+aBG

Z
new decision
E
supplement
Ä
amendment
V
renewal
G
valid until
Subject concerned Applicant Decision no. Validity
from / to
Vorspannsystem BBV Typ i - Litzenspannverfahren zum internen Vorspannen im nachträglichen Verbund und Anwendungsbestimmungen BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim Z-13.1-114 Z: 09.01.2025
G: 02.01.2030
Litzenspannverfahren FUCHS Europoles und Anwendungsbestimmungen FUCHS Europoles GmbH Ingolstädter Straße 51 92318 Neumarkt i. d. OPf. Z-13.1-117 Z: 16.03.2022
G: 04.03.2027
SPANTEC-Vorspannsystem zum internen Vorspannen mit Verbund mittels Litzenspannverfahren für Litzen St 1570/1770 und St 1660/1860, 140 mm² und 150 mm² SPANTEC Spann- & Ankertechnik GmbH Am Geopark 1 86701 Rohrenfels Z-13.1-145 Z: 24.10.2024
G: 25.09.2029
Litzenspannverfahren zur internen Vorspannung mit nachträglichem Verbund von Onshore-Spannbetontürmen mittels Vorspannsystem BBV Typ i BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim Z-13.1-146 Z: 27.03.2025
G: 03.01.2030
Schlaufenverankerung für Spannverfahren mittels Vorspannsystem SUSPA DW nach ETA-13/0839 oder DYWIDAG nach ETA-13/0815 DYWIDAG-Systems International GmbH Neuhofweg 5 85716 Unterschleissheim Z-13.1-148 Z: 12.12.2025
G: 27.11.2030
Vorspannsystem Tele-Mobil Götz - Spannverfahren zum internen Vorspannen von Masten aus Schleuderbeton und Anwendungsbestimmungen Tele-Mobil Götz GmbH Am Grünberg 2 92318 Neumarkt/Pölling Z-13.1-162 Z: 02.09.2024
G: 02.09.2029
Schlaufenverankerung für Spannverfahren mittels Vorspannsystem VSL Post-Tensioning System nach ETA-06/0006 VSL (Schweiz) AG Wankdorfallee 5 3014 BERN SCHWEIZ Z-13.1-164 Z: 30.07.2025
G: 30.07.2030
Vorspannsystem GASTEL - Spannverfahren zum internen Vorspannen von Masten aus Schleuderbeton und Anwendungsbestimmungen GASTEL PREFABRYKACJA S.A. ul. Dworcowa 30A 83-440 KARSIN POMORSKIE POLEN Z-13.1-165 Z: 21.10.2025
G: 21.10.2030
Spannverfahren zur internen Vorspannung mit nachträglichem Verbund von Tragwerken mittels Vorspannsystem 'DYWIDAG Litze' nach ETA-13/0815 DYWIDAG-Systems International GmbH Neuhofweg 5 85716 Unterschleißheim Z-13.71-130815 Z: 22.04.2025
G: 26.06.2028
Anwendungsregeln für das SUSPA-Litze DW Spannverfahren im Verbund mit 1 bis 22 Litzen für das Vorspannen von Tragwerken nach ETA-13/0839 DYWIDAG-Systems International GmbH Neuhofweg 5 85716 Unterschleißheim Z-13.71-130839 Z: 12.12.2025
G: 10.03.2028
Stabspannverfahren zum internen Vorspannen mit nachträglichem Verbund von Tragwerken mittels Vorspannsystem 'BBV 1030' nach ETA-16/0286 BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim Z-13.71-160286 Z: 14.01.2025
G: 21.09.2029
Allgemeine Bauartgenehmigung für das Stabspannverfahren nach ETA-21/0054 "Macalloy 1030" mit nachträglichem Verbund BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim Z-13.71-210054 Z: 15.09.2022
G: 15.09.2027
Anwendungsregeln für das Stabspannsystem für das Vorspannen von Tragwerken, intern mit Verbund nach ETA-05/0122 STAHLWERK ANNAHÜTTE Max-Aicher GmbH & Co. KG Max-Aicher-Allee 1+2 83404 Ainring - Hammerau Z-13.71-50122 Z: 06.11.2023
G: 06.11.2028
Anwendungsregeln für das Spannsystem für das Vorspannen von Tragwerken, intern mit Verbund nach ETA-05/0123 DYWIDAG-Systems International GmbH Neuhofweg 5 85716 Unterschleißheim Z-13.71-50123 Z: 11.07.2023
G: 30.06.2028
Anwendungsregeln für das interne Litzenspannverfahren im Verbund für das Vorspannen von Tragwerken nach ETA-06/0006 vom 20.06.2019 VSL (Schweiz) AG Wankdorfallee 5 3014 BERN SCHWEIZ Z-13.71-60006 Z: 18.04.2023
G: 18.04.2028
Anwendungsregeln für das BBR VT CONA CMI-Spannverfahren im Verbund mit 04 bis 31 Litzen nach ETA-06/0147 vom 30.10.2017 BBR VT International Ltd Ringstrasse 2 8603 SCHWERZENBACH/ZURICH SCHWEIZ Z-13.71-60147 Z: 10.11.2021
G: 23.09.2026
Anwendungsregeln für das Litzenspannverfahren "VBT-KI 4 bis 19" mit nachträglichem Verbund nach ETA-08/0002 vom 23.01.2018 Gleitbau Ges. m.b. H. VBT-Systems Itzlinger Hauptstraße 105 5020 SALZBURG ÖSTERREICH Z-13.71-80002 Z: 08.02.2023
G: 24.01.2028
Subject concerned Applicant Decision no. Issued on
BBV-Internal Bonded Strand Post-tensioning System, type i BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim DEUTSCHLAND ETA-05/0202 04.09.2018
VBT-KI 4 to 19 Gleitbau Ges. m.b. H. VBT-Systems Itzlinger Hauptstraße 105 5020 SALZBURG ÖSTERREICH ETA-08/0002 23.01.2018
VBT - Unbonded Post-tensioning System with 1 to 6 strands VBT Vorspann- und Brückentechnologie GmbH Nierenburger Straße 18 49497 Mettingen DEUTSCHLAND ETA-08/0113 19.06.2018
VBT BE 1 to 16 Gleitbau Ges. m.b. H. VBT-Systems Itzlinger Hauptstraße 105 5020 SALZBURG ÖSTERREICH ETA-10/0006 06.01.2026
BBV External Post-Tensioning System Type E BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim DEUTSCHLAND ETA-11/0123 18.04.2023
BBV L1 P BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim DEUTSCHLAND ETA-13/0810 19.12.2019
Anchor Heads for Ground anchors Richard Münch GmbH Rüther-Münch-Straße 1-3 07926 Gefell DEUTSCHLAND ETA-15/0551 18.12.2025
BBV Anchor Heads for Ground anchors with 2 to 31 strands BBV Systems GmbH Industriestraße 98 67240 Bobenheim-Roxheim DEUTSCHLAND ETA-16/0262 18.12.2025
ENERCON - Post-tensioning System, type i ENERCON GmbH Dreekamp 5 26605 Aurich DEUTSCHLAND ETA-17/0775 08.05.2018