Linearly supported glazing
With linearly supported glazing, the glass panes are continuously fixed via a linear mechanical glass support (e.g. profile) with a glass insertion depth. The glazing system is installed in such a man -
Overhead glazing
Overhead glazing (also known as 'horizontal glazing') is understood to be glazing with an angle of inclination of more than 10° with respect to the vertical plane. With overhead glazing, it is assumed -
Point supported vertical glazing
With point supported glazing, the glass pane is mechanically fixed to the substructure either via point fasteners installed in drilled holes or via clamps (edge clamps). Point supported glazing is use -
Structural sealant glazing
With structural sealant glazing, glass panes are bonded to frame profiles at the factory (primarily using silicone adhesive and with a linear adhesive bead). This prefabricated structural sealant glaz -
Limit switches
Limit switches are safety devices within the meaning of water legislation, installed in tank vehicles and acting together with overfill prevention devices to interrupt the filling operation before the -
Overfill prevention devices
Overfill prevention devices are safety devices within the meaning of water legislation that interrupt the filling operation or trigger an audible/visual alarm before the maximum permitted filling leve -
Fire-resistant damper of special construction technique and application incl. accessories
A fire-resistant damper of special construction technique and application is a construction technique for sealing fire compartments. It mainly consists of a shut-off device integrated into a fire-resi -
Amalgam separators
Amalgam separators serve to treat wastewater containing amalgam residues from treatment units in dental practices. Separator systems -
Leakage detection systems in MSS and biogas facilities
Leakage detection systems are used for detecting leaks in storage and filling facilities for manure, slurry and silage effluent (MSS) and biogas storage and filling facilities (biogas SF facilities), -
Sealing and monitoring systems (with plastic membranes)
Sealing and monitoring systems (with plastic membranes) for use in storage, filling and handling facilities for substances hazardous to water (SFH facilities) usually consist of a multi-layer sealing -
Plastic sheets and membranes, moulding compounds and semi-finished products for sealing tanks and surfaces in SFH facilities
Plastic/sealing sheets and membranes for use in storage, filling and handling facilities for substances hazardous to water (SHF facilities) are manufactured to a specific thickness, laid loosely on th -
Coating materials as well as coating and sealing systems in SFH facilities
Coating materials as well as coating and sealing systems are used for sealing collecting trays, collecting rooms and surfaces in storage, filling and handling facilities for substances hazardous to wa -
Inner coatings and rubber linings for steel tanks for storage of substances hazardous to water
Inner coatings (as partial or full surface coatings) are applied to the inner surfaces of stationary steel tanks for the storage of liquids hazardous to water to make them liquid-tight. Similarly, the -
Fire-retardants for timber
Fire-retardants serve to improve the reaction-to-fire performance of solid timber or wood-based materials treated with them. Through treatment with the fire-retardant, the solid timber or wood-based m -
Fire-protective fabrics
Fire-protective fabrics coated with an intumescent material are used to wrap electrical cables and services to improve their reaction-to-fire performance and/or to impede the breakout and spread of a -
Fire-resistant glazing
Fire-resistant glazing is a non-load-bearing building component, usually consisting of one or more translucent elements, a frame and fixings, seals and fasteners which meet specific fire-resistance re -
Sanitary appliances
Sanitary appliances refer to those parts of a sanitary installation through which accumulating rainwater, foul or waste water is fed into the property drainage system (e.g. WCs, urinals, showers, bath -
Non-return valves for drainage systems
Non-return valves serve to prevent backflow of rainwater or wastewater from the connected sewer system into the parts of the property drainage system lying below the backwater level. Equipment for dra -
Sewage lift stations
Sewage lift stations are used to pump sewage from below the backwater level upwards so it can be drained via the public sewer system. Sewage lift stations usually have cutting devices for reducing the -
Thermal insulation products for heating appliances
These special thermal insulation products may be used as thermal insulation or substitutes for masonry facing and thermal insulation on stationary heating appliances assembled on site (e.g. stoves and -
Ventilation units with heat pump
In ventilation units using heat pump technology, the ambient heat, e.g. the heat from the earth or the heat from the outside air, is used for space heating. Common variants include: ventilation unit w -
Flue gas heat exchangers
Flue gas heat exchangers transfer the thermal energy from the heating appliance flue gas to the heating water. This increases the efficiency of the heating system. Heating appliances, chimneys -
Concrete admixtures
Concrete constituents -
Shear connectors
Shear connectors, such as anchors, power-actuated fasteners or composite dowel beams, are used in composite members to connect the steel and concrete components in a form-fitting manner. When the comp -
Composite columns
Composite columns consist of a combination of steel sections and concrete or reinforced concrete. The steel sections are completely or partially embedded in concrete. Composite columns have much highe