Safety devices with position monitoring for combined operation of ventilation systems and non-room-sealed heating appliances
Stand-alone safety devices for monitoring the opening state of a window ensure that ventilation systems and non-room-sealed heating appliances can be operated safely in combined operation mode. If the -
Safety devices with differential pressure monitoring for combined operation of ventilation systems and non-room-sealed heating appliances
Stand-alone safety devices with differential pressure monitoring serve to ensure that ventilation systems and non-room-sealed heating appliances can be operated safely in combined operation mode. For -
Falsework beam clamps
Falsework beam clamps are connectors in falsework in accordance with EN 12812 with a mechanical fit based on contact pressure and friction. The contact pressure is activated through bolt connections. -
Scaffold couplers
Scaffold couplers in accordance with EN 74-1 or EN 74-2 are the most common form of detachable connectors in scaffolding. They usually provide an interference fit between scaffold tubes. Couplers are -
Shoring props
Telescopic and non-telescopic props made of steel in accordance with EN 1065 or aluminium in accordance with EN 16031 are used on construction sites as temporary vertical supports during construction -
Dust separators for firing systems
Dust separators are used in chimneys to reduce the dust particle content of flue gases resulting from the combustion of solid fuels. Heating appliances, chimneys -
Waterproofing sheets and membranes
Waterproofing sheets and membranes are available for various applications (e.g. for roofs or elements in contact with soil). Waterproofing sheets and membranes can be divided into plastic and bitumen -
Asphalt sealing layers in MSS and biogas facilities
Mastic or roller-compacted asphalt sealing layers are used in storage and filling facilities for manure, slurry and silage effluent (MSS facilities) and biogas storage and filling facilities (biogas S -
Drainage channel systems and penetrations in MSS and biogas facilities
Drainage channel systems and penetrations in retaining systems need to be designed in a way to ensure that no substances hazardous to water can escape from storage and filling facilities for manure, s -
Joint sealing systems in MSS and biogas facilities
Joint sealing systems, e.g. sealing strips, sealing sheets, sealing tapes, coated sealing sheets and sealing compounds, serve to make construction joints in sealing surfaces or sealing systems of stor -
Asphalt sealing layers in SFH facilities
Mastic or roller-compacted asphalt sealing layers are used in storage, filling and handling facilities for substances hazardous to water (SFH facilities) to create load-bearing, liquid-tight, sealed s -
Systems for restoring leak tightness in SFH facilities
Systems for restoring the leak tightness of sealing systems made of concrete in storage, filling and handling facilities for substances hazardous to water (SFH facilities) are used for the repair of d -
Semi-rigid sealing layers, drainage channel systems and penetrations in SFH facilities
Semi-rigid sealing layers are used to create load-bearing surfaces in retaining systems, e.g. collecting rooms, collecting trays and surfaces, in storage, filling and handling facilities for substance -
Joint sealing systems and fixings in SFH facilities
Joint sealing systems in SFH facilities Joint sealing systems, e.g. sealing strips, sealing sheets, compression profiles, extruded profiles, sealing tapes, coated sealing sheets and sealing compounds, -
Steel and steel composite sealing systems in SFH facilities
Steel and steel composite sealing systems serve to make retaining systems such as collecting rooms, collecting trays and surfaces in storage, filling and handling facilities for substances hazardous t -
Sealing systems made of concrete in SFH facilities
To create (load-bearing) surface seals for retaining systems, such as collecting trays, rooms or surfaces, in storage, filling and handling facilities for substances hazardous to water (SFH facilities -
Balanced flue systems
Balanced flue systems are room-sealed appliances, meaning that instead of using the air of the heating room as combustion air, outside air is supplied to the appliance. Balanced flue systems convey co -
Fittings, components and thermal insulation products for chimneys
Chimneys for solid fuels serve to discharge flue gases from the combustion of solid fuels into the outside atmosphere via an outlet above roof level. They can also be used to discharge flue gases from -
Cross-sectional reductions for chimneys
Cross-sectional reductions for existing chimneys are used for renovation and/or modernisation. The purpose may be to upgrade the chimney for operation under wet conditions or adapt the cross section o -
Catalysts for firing systems
Catalysts are used in firing systems to optimise the combustion processes and reduce the amount of harmful flue gas substances produced. Heating appliances, chimneys -
Special fittings for tanks for substances hazardous to water
Various construction products that serve as safety devices within the meaning of water legislation and contribute to preventing damage to water bodies are referred to as 'special fittings for tanks fo -
Closures and closure systems for inspection openings
Closures and closure systems for inspection opening are used to seal revision openings in fire-resistant service ducts or suspended ceilings inside a building or structural work. They prevent fire or -
Fixings bonded to the roof waterproofing
For penetration-free fixing of photovoltaic systems or fall protection to the roof, the fixings can be bonded or welded to the roof waterproofing membrane. The roof waterproofing thus takes on a struc -
Walk-on glazing, accessible glazing and glazing with fall-through protection
Walk-on glazing is designed for foot traffic. A vertical imposed load of maximum 5 kN/m 2 is assumed under normal use conditions. Glazing accessible for maintenance and glazing with fall-through prote -
Barrier glazing
Barrier glazing is glazing designed to prevent people from falling to a lower level. In the event of impact on the glazing, the risk of injury is supposed to be low. Furthermore, the lower-lying traff